Skip to main content
Oven / Range Pro Recommended

Thermador E118 — Thermador Oven E118 — Temperature Sensor Failure

What This Code Means

The oven temperature probe (NTC sensor) is reading outside the valid range. The control unit cannot confirm a valid cavity temperature and will not allow cooking modes to operate.

Common Causes

  • Failed NTC temperature sensor
  • Burned wiring harness to the sensor (common after extended self-clean cycles)
  • Control board sensor input circuit failure

DIY Steps to Try First

  1. Power cycle the oven at the breaker.
  2. Inspect the sensor probe at the top-rear of the oven cavity — look for visible wire damage near the ceramic insulator.
  3. On Thermador models, the sensor NTC resistance should be approximately 1000 ohms at 25°C (77°F). An OL reading indicates failure.